VATE INNOVATE CORP

MediBeacon® Transdermal GFR System Receives FDA Approval to Assess Kidney Function

MediBeacon® Transdermal GFR System Receives FDA Approval to Assess Kidney Function

  • Transdermal GFR System (TGFR) is a first-in-kind product for point of care assessment of kidney function in patients with normal or impaired renal function
  • The transdermal GFR (tGFR) methodology has been designed to be effective across the adult population without input of age, weight, sex, gender, race, or ethnicity
  • More than 800 million people have Chronic Kidney Disease (CKD), one of the world’s leading causes of mortality worldwide, with associated deaths increasing over the past two decades1

NEW YORK, Jan. 17, 2025 (GLOBE NEWSWIRE) -- INNOVATE Corp. (NYSE: VATE) (“INNOVATE” or the “Company”) announced today that the U.S. Food and Drug Administration (FDA) has approved the MediBeacon® TGFR for the assessment of kidney function in patients with normal or impaired renal function.

The TGFR is comprised of the TGFR Sensor, TGFR Monitor, and Lumitrace® (relmapirazin) injection, a non-radioactive, non-iodinated fluorescent GFR tracer agent, which together allow assessment of kidney function by measuring the clearance rate of the fluorescent agent as it leaves the body. The system records Lumitrace fluorescence intensity transdermally as a function of time via a sensor placed on the skin. The TGFR Sensor records 2.5 fluorescent readings per second and the TGFR Monitor will display the average session tGFR reading at the patient’s bedside or in the outpatient setting.

The TGFR is validated for use in the assessment of Glomerular Filtration Rate (GFR) in patients with stable kidney function at the point of care. The TGFR utilizes an intravenous Lumitrace injection but does not require blood draws or urine analysis, unlike current methodologies requiring multiple blood draws or urine samples. In addition, current clinical practice measured GFR (mGFR) assessment requires sophisticated clinical laboratory analysis away from the patient’s point of care.

“The development of a system such as the TGFR that assesses a patient’s kidney function without the need to use estimating equations is an important milestone for the nephrology community,” said Dr. Mitchell Rosner, chair of the Department of Medicine at University of Virginia and a highly regarded expert who has authored numerous articles on the challenges of assessing kidney function. “We are excited to explore applications of the transdermal GFR methodology in patients where current clinical practice is understood to be suboptimal.”

Dr. Pierre Galichon, an active kidney researcher at the Sorbonne Université and an attending physician in kidney transplantation at Pitié-Salpêtrière Hospital in Paris, said: “It has long been a challenge to understand kidney function in the context of its interaction with other vital organs, such as the heart and lungs. My experience with MediBeacon products in preclinical use, as relayed in Scientific Reports,2 has been exciting, and I look forward to evaluating how transdermal GFR can be applied in clinical practice.”

“The approval of the TGFR by the FDA demonstrates our proprietary system can provide an effective option for assessing kidney function,” said Steve Hanley, CEO of MediBeacon. “According to the National Kidney Foundation, CKD causes more deaths each year than breast cancer or prostate cancer. It is the under-recognized public health crisis.3 The potential applications for the TGFR are numerous, and we look forward to exploring them with clinicians both in the hospital and outpatient settings.”

The timing of FDA approval aligns well with the Q4 2024 publication by MediBeacon’s Chief Scientific Officer, Dr. Richard Dorshow, et al. in Kidney International with data that supports the utility of MediBeacon’s patented agent Lumitrace®.

The TGFR met its primary efficacy endpoint as per agreement with the FDA by demonstrating a P30 value of 94% while recruiting patients with a range of GFR values and skin tones. P30 is defined as the percentage of GFR estimation falling within +/- 30% of measured GFR (mGFR) values.



P30 ValueUpper 95% Confidence BoundsLower 95% Confidence Bounds
94.0%96.9%89.4%



In clinical studies no serious or severe adverse events have been observed. For more information, including the FDA Summary of Safety and Effectiveness Data, please refer to

About INNOVATE

INNOVATE Corp. is a portfolio of best-in-class assets in three key areas of the new economy – Infrastructure, Life Sciences and Spectrum. Dedicated to stakeholder capitalism, INNOVATE employs approximately 4,000 people across its subsidiaries. For more information, please visit: .

About MediBeacon Inc.

MediBeacon is a medical technology company specializing in the advancement of fluorescent tracer agents and their transdermal detection. MediBeacon’s use of proprietary fluorescent tracer agents coupled with transdermal detection technology focuses on providing vital and actionable measurement of organ function. MediBeacon owns over 55 granted U.S. patents and over 215 granted patents worldwide that provide extensive coverage of the MediBeacon® TGFR, including Lumitrace® injection, the sensor and algorithms, as well as other strategic uses of its proprietary pyrazine platform and sensor technology. The TGFR is approved for human use. Potential technology applications in gastroenterology, ophthalmology and surgery are in various stages of clinical development. MediBeacon is based in St. Louis, Missouri, with additional operations in Mannheim, Germany. For more information, please visit: .

About Lumitrace® (relmapirazin) injection

Relmapirazin is a non-radioactive, non-iodinated pyrazine-based compound, which has been engineered to be inert, highly fluorescent and have the clearance properties of a GFR tracer agent in the body. Lumitrace injection has been administered to over 850 subjects under Investigational Device Exemptions (IDEs). The unique photophysical characteristics of Lumitrace have been designed to enable the collection of fluorescence data via a photodetector sensor placed on the skin. Data collected by the sensor measures the change in the intensity of Lumitrace fluorescence over time and is converted into a transdermal GFR (tGFR) by proprietary algorithms. As noted above, in a phase 2 investigational study mGFR deduced from Lumitrace matched that of mGFR deduced from iohexol over a range of GFR values. See the peer reviewed article published in the October 2024 issue of Kidney International4 by Dorshow et al.

Forward-Looking Statements

Certain statements in this press release may constitute “forward-looking statements” within the meaning of the federal securities laws. Forward-looking statements generally relate to future events, such as the expected timing of the reverse stock split, the impact of the reverse stock split on the Company’s share price, and the Company’s ability to meet the minimum per share bid price requirement for continued listing on the NYSE. You are cautioned that such statements are not guarantees of future performance and that INNOVATE’s actual results may differ materially from those set forth in the forward-looking statements. All of these forward-looking statements are subject to risks and uncertainties that may change at any time. Factors that could cause INNOVATE’s actual expectations to differ materially from these forward-looking statements include INNOVATE’s ability to continue to comply with applicable listing standards of the NYSE and the other factors under the heading “Risk Factors” set forth in INNOVATE’s Annual Report on Form 10-K, as supplemented by INNOVATE’s quarterly reports on Form 10-Q. Such filings are available on our website or at You should not place undue reliance on these forward-looking statements, which are made only as of the date of this press release. INNOVATE undertakes no obligation to publicly update or revise forward-looking statements to reflect subsequent developments, events, or circumstances, except as may be required under applicable securities laws.

Investor Contact:

Solebury Strategic Communications

Anthony Rozmus



(212) 235-2691

IMPORTANT SAFETY INFORMATION FOR TGFR

Indication for Use:

The MediBeacon® Transdermal GFR System (TGFR) is intended to assess the Glomerular Filtration Rate (GFR) in adult patients with impaired or normal renal function by noninvasively monitoring fluorescent light emission from an exogenous tracer agent over time. The MediBeacon TGFR consists of a monitor and a sensor, which are to be used with the Lumitrace® tracer only. This device has been validated in patients with stable renal function.

The MediBeacon TGFR is not approved for use in patients with GFR <15ml/min/1.73m2, GFR >120ml/min/1.73m2, patients on dialysis or anuric patients. The use of this device in patients with dynamic and rapidly changing renal function has not been validated. This device is not intended to diagnose acute kidney injury (AKI).

Contraindications:

There are no known contraindications.

Warnings and Precautions:

  • See ifu.medibeacon.com for full instructions, warnings, and cautions.
  • In clinical studies no serious or severe adverse events have been observed.
  • Lumitrace® injection has light absorbance at 266nm and 435nm, and broad fluorescent emission at ~560nm when excited at ~440nm. Any drug activated at these wavelengths should not be used in conjunction with Lumitrace.
  • Lumitrace injection may interfere with clinical laboratory tests. DO NOT ADMINISTER if the patient is expected to need clinical laboratory testing while Lumitrace is present in their system (up to 72 hours for renally-impaired patients). The presence of Lumitrace decreased B-Type Natriuretic Peptide (BNP) results by around 20% in limited testing.
  • Bolus infusions may impact the GFR assessment temporarily while the vasculature-tissue equilibrium is re-established.
  • During a TGFR session, the patient should be as still as possible, especially during the “Establishing Baseline” stage. The current system is designed to compensate for light activity such as reading or eating after the Baseline stage.

1 Epidemiology of chronic kidney disease: an update 2022, Kidney International Supplement, 2022 Apr;12(1):7-11.

, Csaba P Kovesdy

2 Pulmonary hypertension without heart failure causes cardiorenal syndrome in a porcine model, Scientific Reports (2023) 13:9130, Orieux et al, 

3 National Kidney Foundation, Fast Facts (2024 Update), Updated as of 8/6/2024

Clinical validation of the novel fluorescent glomerular filtration rate tracer agent relmapirazin (MB-102), Kidney International, Volume 106, Issue 4, P679-687, October 2024, DOI: 



EN
17/01/2025

Underlying

To request access to management, click here to engage with our
partner Phoenix-IR's CorporateAccessNetwork.com

Reports on INNOVATE CORP

 PRESS RELEASE

MediBeacon® Transdermal GFR System Receives FDA Approval to Assess Kid...

MediBeacon® Transdermal GFR System Receives FDA Approval to Assess Kidney Function Transdermal GFR System (TGFR) is a first-in-kind product for point of care assessment of kidney function in patients with normal or impaired renal functionThe transdermal GFR (tGFR) methodology has been designed to be effective across the adult population without input of age, weight, sex, gender, race, or ethnicityMore than 800 million people have Chronic Kidney Disease (CKD), one of the world’s leading causes of mortality worldwide, with associated deaths increasing over the past two decades1 NEW YORK, J...

 PRESS RELEASE

INNOVATE Corp. Portfolio Company R2 Technologies Announces Another Rec...

INNOVATE Corp. Portfolio Company R2 Technologies Announces Another Record-Breaking Quarter and Partnerships with Woodhouse Spas and Top Skincare Brands NEW YORK, Nov. 20, 2024 (GLOBE NEWSWIRE) -- R2 Technologies, Inc., the world leader in CryoAesthetics® with its cutting-edge Glacial Skin systems (“R2”), a portfolio company of INNOVATE Corp. (NYSE: VATE) (“INNOVATE” or the “Company”) announced today that it has achieved several impressive milestones during 2024. The growing momentum of the brand coupled with recent key partnerships has positioned the company for substantial growth across ...

 PRESS RELEASE

INNOVATE Corp. Announces Third Quarter 2024 Results

INNOVATE Corp. Announces Third Quarter 2024 Results - Infrastructure: DBM Global third quarter revenue of $232.8 million -- Life Sciences: R2 reports record worldwide system unit sales growth in the third quarter -- Spectrum: Broadcasting's delivered another quarter of strong growth driven by network launches - NEW YORK, Nov. 06, 2024 (GLOBE NEWSWIRE) -- INNOVATE Corp. (“INNOVATE” or the “Company”) (NYSE: VATE) announced today its consolidated results for the third quarter. Financial Summary (in millions, except per share amounts)Three Months Ended September 30, Nin...

 PRESS RELEASE

INNOVATE Corp. to Report Third Quarter 2024 Results on November 6th

INNOVATE Corp. to Report Third Quarter 2024 Results on November 6th NEW YORK, Oct. 16, 2024 (GLOBE NEWSWIRE) -- INNOVATE Corp. (NYSE: VATE) (“INNOVATE” or the “Company”) announced today that it will release its financial results for the third quarter 2024 on Wednesday, November 6, 2024, after market close. The Company will host an earnings conference call reviewing these results, its operations and strategy on the same day, beginning at 4:30 p.m. ET. Dial-in instructions for the conference call and the replay are outlined below. This conference call will also be broadcast live over the i...

 PRESS RELEASE

INNOVATE Corp. Regains Compliance with NYSE Minimum Price Requirement

INNOVATE Corp. Regains Compliance with NYSE Minimum Price Requirement NEW YORK, Sept. 03, 2024 (GLOBE NEWSWIRE) -- INNOVATE Corp. (NYSE: VATE) (“INNOVATE” or the “Company”) announced today that it has received a letter from the New York Stock Exchange (“NYSE”) dated August 27, 2024 (the “Compliance Notice”), notifying the Company that it is no longer considered below the NYSE’s continued listing criterion of a minimum average share price of US $1.00 over a 30 trading-day period (the "NYSE Minimum Price Requirement"). “The INNOVATE team is pleased to share that we have received notificati...

ResearchPool Subscriptions

Get the most out of your insights

Get in touch