300750 CONTEMPORARY AMPEREX TECHNOLOGY CO

EQS-News: Volta Medical Artificial Intelligence-Guided Cardiac Ablation Procedure Improves Treatment of Atrial Fibrillation

EQS-News: Volta Medical SAS / Key word(s): Study results
Volta Medical Artificial Intelligence-Guided Cardiac Ablation Procedure Improves Treatment of Atrial Fibrillation

14.02.2025 / 11:30 CET/CEST
The issuer is solely responsible for the content of this announcement.


Volta Medical Artificial Intelligence-Guided Cardiac Ablation Procedure Improves Treatment of Atrial Fibrillation

  • AI-Guided Cardiac Ablation in combination with pulmonary vein isolation was superior to the standard of care in the treatment of Persistent Atrial Fibrillation.
  • Volta Medical Announces Publication of Landmark Clinical Trial in Nature Medicine. This trial marks the first large-scale demonstration of the benefits of AI in interventional cardiology.

Marseille (France), February 14, 2025 – Volta Medical, a pioneering health technology company developing artificial intelligence (AI) solutions to assist electrophysiologists, today announced the publication of the landmark TAILORED-AF clinical trial in Nature Medicine, which demonstrated that an AI-guided procedure for persistent atrial fibrillation (AF) in combination with conventional pulmonary vein isolation (PVI) treatment, resulted in better outcomes than PVI alone. In particular, the study showed superiority in the percentage of patients that achieved freedom from AF with or without anti-arrhythmic drugs at 12 months after a tailored cardiac ablation guided by AI in combination with PVI when compared to PVI alone. Despite advances in catheter ablation technology, persistent AF remains one of the most challenging subtypes of atrial fibrillation to treat, affecting over 70% of all patients with AF globally.i

The TAILORED-AF clinical trial is the first large-scale transatlantic randomized controlled trial (RCT) of ablation in a persistent AF population to show the benefit of going beyond conventional PVI-only extra-pulmonary vein procedure. Previous studies looking at ablation strategies for persistent AF patients have not demonstrated superior efficacy to PVI alone. The Volta AF-Xplorer™ is a digital AI companion designed to assist cardiologists with real-time identification of specific abnormal electrograms (EGMs) known as spatio-temporal dispersed EGMs, this technology was used in the TAILORED-AF trial.

“Previously, there has not been a replicable, effective treatment strategy for patients with persistent atrial fibrillation. Volta’s AI solution finally offers a solution for this large and underserved patient population,” said Théophile Mohr-Durdez, CEO and co-founder of Volta Medical. “The TAILORED-AF trial, highlights AI’s ability to help physicians treat cardiovascular disease and improve patient outcomes. In fact, this is the first large-scale international RCT in interventional cardiology demonstrating superior efficacy through the use of AI.”

Summary and Results: Tailored vs. Anatomical Ablation Strategy for Persistent Atrial Fibrillation (TAILORED-AF) Study
In the clinical trial, adults with symptomatic persistent or long-standing persistent AF who were candidates for a first-time ablation were enrolled in Europe and the United States. A total of 187 patients underwent a tailored cardiac ablation guided by Volta’s AI in addition to PVI (Tailored cohort), and 183 patients received the conventional treatment of PVI-only (Anatomical cohort) and all were followed up for 12 months.  A total of 51 electrophysiologists at 26 centers in 5 countries across the US and EU participated. For access to the full publication visit .

The trial met the primary endpoint by demonstrating superior results in patients assigned to the Tailored cohort compared to the Anatomical cohort.

  • 88% of patients in the Tailored cohort experienced freedom from AF 12 months after one procedure with or without anti-arrhythmic drugs compared to 70% in the Anatomical cohort (log rank p < 0.0001).
  • In the Tailored cohort, patients experienced a higher rate of freedom from any arrhythmia after 1.2 procedures than in the Anatomical cohort (79% vs. 71%, log rank p < 0.01).  Recurrences in the Tailored cohort were regarded as a “simplification” of AF which are generally easier to ablate and can be seen as a step towards stable sinus rhythm.
  • The trial also examined several pre-specified secondary endpoints and a pre-specified subgroup analysis of patients with sustained persistent AF lasting 6 months or longer prior to enrollment. These patients represent a more advanced AF disease progression. Patients in the Tailored cohort experienced a significantly higher rate of freedom from any arrhythmia after one single procedure than in the Anatomical cohort (62% vs. 48%, log rank p = 0.04).
  • The safety endpoint did not differ between the groups, although the procedure and ablation time were twice as long in the Tailored arm, consistent with treatment time for other PVI+ methods.

“Atrial fibrillation, when left untreated, doubles the risk of heart-related deaths and is associated with a 5-fold increased risk for stroke. However, advancements in AI are transforming this landscape,” said  Professor Isabel Deisenhofer, German Heart Center Munich Department of Electrophysiology. “This trial featuring AI-guided assessment of AF represents a true milestone for improvement of outcomes for this underserved and difficult to treat patient community.”

About Atrial Fibrillation

The American Heart Association defines AF as a quivering or irregular heartbeat (arrhythmia) that can lead to blood clots, stroke, heart failure, and other heart-related complications.ii. Approximately 33 million patients worldwide are living with AF.iii,iv Even though untreated AF doubles the risk of heart-related deaths and is associated with a 5-fold increased risk for stroke, many patients are unaware that AF is a serious condition. It is estimated that only 15% of the eligible 2.5 million US patients with AF are currently being treated with catheter ablation.v

About Volta Medical

Volta Medical is a health technology company developing artificial intelligence software solutions with the aim of assisting cardiac electrophysiologists during arrhythmia treatment procedures to improve clinical outcomes for patients. Founded by three physicians and a data scientist in 2016 in Marseille, France, the company’s mission is to improve cardiac arrhythmia management by developing state-of-the-art, data-driven medical devices trained on large databases of procedural data. The Volta AF-Xplorer™ is a digital AI companion designed to assist cardiologists with real-time identification of specific abnormal electrograms (EGMs) known as spatio-temporal dispersed EGMs during AF and atrial tachycardia procedures. The AF-Xplorer™ has been engineered for versatility and its use has been demonstrated with the most popular AF mapping and recording systems, as well as with the most common ablation modalities. The solution is U.S. FDA 510(k) cleared and European CE Mark approved. For more information, visit the company’s website at .

Volta Contact
Jeff Martin, SVP of Global Marketing
Volta Medical

European Media Contact
Brittney Sojeva
MC Services AG

References

  1. David DeLurgio, Jaswinder Gill, Syed Ahsan, Riyaz Kaba, Kristen M Plasseraud, Michael E Halkos, Hybrid Convergent Procedure for the Treatment of Persistent and Long-standing Persistent Atrial Fibrillation, Arrhythmia & Electrophysiology Review 2021;10(3):198–204.
  2. /en/health-topics/atrial-fibrillation [last accessed June 9, 2023]
  3. Colilla S, Crow A, Petku W, Singer DE, Simon T, Liu X. Estimates of current and future incidence and prevalence of atrial fibrillation in the U.S. adult population. Am J Cardiol 2013; 112:1142–1147. DOI: 10.1016/j.amjcard.2013.05.063
  4. -vorhofflimmern.de/en [last accessed June 9, 2023]
  5. /cardiovascular/medtronic-makes-a-double-play-for-atrial-fibrillation


14.02.2025 CET/CEST Dissemination of a Corporate News, transmitted by EQS News - a service of EQS Group.
The issuer is solely responsible for the content of this announcement.

The EQS Distribution Services include Regulatory Announcements, Financial/Corporate News and Press Releases.
Archive at -news.com


Language: English
Company: Volta Medical SAS
65 Avenue Jules Cantini
13006 Marseille
France
E-mail:
Internet: -medical.com
EQS News ID: 2085373

 
End of News EQS News Service

2085373  14.02.2025 CET/CEST

fncls.ssp?fn=show_t_gif&application_id=2085373&application_name=news&site_id=research_pool~~~9efe1c65-8ece-4ff7-9608-f21c8e0a38a3
EN
14/02/2025

Underlying

300750CONTEMPORARY AMPEREX TECHNOLOGY CO

To request access to management, click here to engage with our
partner Phoenix-IR's CorporateAccessNetwork.com

Reports on CONTEMPORARY AMPEREX TECHNOLOGY CO

 PRESS RELEASE

EQS-News: vbw Pressemitteilung zum Koalitionsvertrag: Gute Grundlage

Emittent / Herausgeber: ibw – Informationszentrale der Bayerischen Wirtschaft e. V. / Schlagwort(e): Sonstiges/Sonstiges vbw Pressemitteilung zum Koalitionsvertrag: Gute Grundlage 10.04.2025 / 09:30 CET/CEST Für den Inhalt der Mitteilung ist der Emittent / Herausgeber verantwortlich. vbw zum Koalitionsvertrag: Gute Grundlage Brossardt: „Koalitionsvertrag schafft Planungssicherheit und setzt Wachstumsimpulse“  Bertram Brossardt, Hauptgeschäftsführer der vbw – Vereinigung der Bayerischen Wirtschaft e. V.: (München, 09.04.2025). Wir freuen uns, dass jetzt der Weg frei ist f...

 PRESS RELEASE

Aquis Stock Exchange - suspension of trading

Aquis Stock Exchange Aquis Stock Exchange - suspension of trading 10-Apr-2025 / 07:00 GMT/BST The issuer is solely responsible for the content of this announcement. The following securities are suspended from trading on the Aquis Growth Market from 08.00, 10 April 2025, at the request of the company: Richmond Hill Resources Plc Ordinary Shares Symbol: SHNJ ISIN: GB00BNTBWF32 The Regulation Department Aquis Stock Exchange Floor 2, 63 Queen Victoria Street, EC4N 4UA Tel: 0203 597 6361 Email:  Website:  Dissemination of a CORPORATE NEWS, transmitted by EQS Group.The i...

 PRESS RELEASE

EQS-News: CO2Coin one of the most successful crypto investments of the...

Issuer: Clima4Future Ltd. / Key word(s): Cryptocurrency / Blockchain/Market Launch CO2Coin one of the most successful crypto investments of the coming decades. 10.04.2025 / 04:55 CET/CEST The issuer is solely responsible for the content of this announcement.     CO2Coin is going through a phase of phenomenal growth. A year ago the price was just €1, today it is around 270 USDT - an increase in value that illustrates the enormous potential of this unique project. This development reflects the crypto community's growing interest in sustainable investments. Clima4Future Lt...

 PRESS RELEASE

EQS-News: CO2Coin eine der erfolgreichsten Krypto-Investitionen der ko...

Emittent / Herausgeber: Clima4Future Ltd. / Schlagwort(e): Kryptowährung / Blockchain/Markteinführung CO2Coin eine der erfolgreichsten Krypto-Investitionen der kommenden Jahrzehnte. 10.04.2025 / 04:55 CET/CEST Für den Inhalt der Mitteilung ist der Emittent / Herausgeber verantwortlich. Der CO2Coin hat einen beeindruckenden Kursanstieg erlebt. Vor einem Jahr lag der Kurs noch bei 1 €, heute liegt er bei rund 270 USDT - eine Wertsteigerung, die das enorme Potenzial dieses einzigartigen Projekts verdeutlicht. Diese Entwicklung spiegelt das wachsende Interesse der Krypto-Com...

 PRESS RELEASE

EQS-News: Zimbabwe Government Delivers on Commitment: Compensation of ...

EQS-News: Zimbabwe Ministry of Finance, Economic Development and Investment Promotion / Key word(s): Miscellaneous Zimbabwe Government Delivers on Commitment: Compensation of Former Farm Owners under the Global Compensation Deed Commences 09.04.2025 / 20:20 CET/CEST The issuer is solely responsible for the content of this announcement. In line with the GCD agreement, the FFOs receive 1 per cent of their claim in cash, with the balance being paid through US$ denominated Treasury bonds with a 2 per cent coupon and maturities of 2 to 10 years HARARE, Zimbabwe, April 9, 2025...

ResearchPool Subscriptions

Get the most out of your insights

Get in touch